Minimum Firmware Requirement

Any DFE blade that has an uplink slot must be updated to firmware release 5.41.25 or higher 5.42.xx is recommended — before the 7G-6MGBIC-B module is installed.

If the firmware is not updated the result will be a boot error message on the CLI and in the Fault Log and the blade will fail Initialization Diagnostics:

Running Initialization Diagnostics...  FAILED
Unsupported Uplink Board Revision

Minimum DFE Blade Hardware Requirement

The 7G-6MGBIC-B uplink module has the following minimum DFE blade hardware requirements:

Part DFE Blade DescriptionMinimum Hardware Revision
7H4385-49 Matrix N–Series Platinum DFE with 48 10/100 Ethernet ports via RJ45 connectors, Supports Power over Ethernet (PoE) and NEM 0U
4H4285-49 Matrix N-Series Gold DFE with 48 10/100 Base-TX ports via RJ45 connectors, PoE, 1 Expansion Slot 0V

Note: This tech tip does not apply to the 7G-6MGBIC-A uplink module.